Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameATLANTIC MOUNTAIN ISLAND THE
Address10410 COOKS WAY DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/31/2023
Final Score @ Grade
34
General CommentsInspection conducted with operator, Melvin. Immediate suspension of the permit issued due to chlorine less than 1.0, inaccessible ring buoy, and emergency phone system not operating properly. Pool closed with gates locked and signs posted during inspection. Once items are corrected, call Hope McIntosh at 980-229-7549 for a re-inspeciton. Pool may not re-open until permit suspension is lifted. Once the above items are corrected, a 30 day intent to suspend the permit may be issued if the following items remain non-compliant: Fence repair Missing spare pump basket Night swimming is not permitted.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Chlorine at 0.2ppm *immediate suspension item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing or damaged skimmer basket. Damaged skimmer basket on 3.5ft end of pool. Replaced during inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment should be conveniently located. Ring buoy rope rolled and tied such that it is not immediately accessible in the event of an emergency. Rope must be untied so that buoy is usable. *Immediate suspension item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528 (a) - damaged fencing in corner such that entire panel is detached from post. Repair *permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Area of damaged concrete on far side of pool near coping with offset approaching 1/2” present. Repair prior to permitting for 2024 season.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Kings III cellular emergency system not operating properly. EHS attempted to use system 4 times before it connected. Kings III operator noted there may be a poor signal and that location must call and request service to remedy. Box speaker is not clear and fades in and out such that significant portions of conversation with 911 operator unclear. Box not programmed to receive call back. *Immediate suspension item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(e) Provide a spare basket for pump. Missing spare pump basket. *permit item