5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (4) Lower and maintain cyanuric acid at or below 100 ppm.
Observed gaps in the log record. No permit action taken. Keep the records properly. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable. Emergency phone failed during the inspection due to community wide lost of tel-com utility service during the inspection. C. Elmore will follow-up on 4/16/2026. Immediate Suspension issued. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Observed chlorination system not on-line upon arrival. System was brought on-line during the inspection. -CDI. Disinfectant must be maintained through the disinfectant system. It cannot be manually fed into the water for normal operation. It may only be manually fed for shocking or maintenance operations when the pool is kept closed until normal operation with the disinfectant feeder system is resumed. |