3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be higher than 8.4. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (4) Lower and maintain cyanuric acid at or below 100 ppm.
Observed gaps in the log recored. No permit action taken. Keep the records properly. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed 1 missing weir. No permit action taken. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable. Emergency phone failed during the inspection due to community wide lost of tel-com utility service during the inspection. C. Elmore will follow-up on 4/16/2026. Immediate Suspension issued. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Observed chlorination system not on-line upon arrival. System could not be brought on-line to function properly during the inspection. Disinfectant must be maintained through the disinfectant system. It cannot be manually fed into the water for normal operation. It may only be manually fed for shocking or maintenance operations when the pool is kept closed until normal operation with the disinfectant feeder system is resumed. A properly functioning disinfectant system must be on-line for the spa to be open. |