Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCRESSWIND HOA SPA
Address9304 CRESSWIND BLVD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 9/17/2025
Final Score @ Grade
26
General CommentsMain drains expire 12/19/2028. Observed the WFK 4 1 HP pump and motor system replaced like for like. This does not require a PDSC form as it was a like for like swap, but it does require an electrical inspection with Code Enforcement. It is not clear if an electrical inspection was done. C. Elmore will follow-up on or around 9/24/2028.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be higher than 8.4. Corrected during the inspection to 7.8
4 6 Water quality: water temperature of heated pool No No No .2535(12) Heated spa temperature greater than 104 F. Maintain spa temperature at 104 F or below. Observed the temp to be 104.7F. It cannot be higher than 104F. Corrected to 103.2F. Ensure temperature does not go above 104F.
14 4 Pool maintenance: spa timer working properly No No No .2537(b) Spa times shall not exceed 15 minutes without manual resetting. Observed spa timer for the jets to run for 16 minutes and 14 seconds. Jets were turned off. Correct the timer to run 15 minutes or less before returning the jets to operation.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed audible alarms non-functional. They were corrected during the inspection.
20 4 Premises: caution signs posted at hot water spas No No No Observed custom spa sign posted and previously correct sign removed. New correct sign was posted. The custom sign can remain, but correct signs must remain posted.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed leaks that are causing wet conditions in parts of the pump room and may be negatively affecting equipment if it is getting wet from the spray of the leaks. Correct these leaks.