Inspection Date 9/23/2025
Final Score @ Grade
18
General CommentsPerformed inspection with CPO Elvis. Immediate suspension issued for chlorine level. Permit suspended and pool must close. Call EHS Devon when corrected and ready for re inspection. Flow meter and records must be corrected upon return visit or intent to suspend may be issued. No night swimming Const. Date: 9/1/2003 Rope Length: 50' PERMIT RESTRICTION: PUMP REQUIRED LOCKED AT MAX SPEED (3450 RPM) TO MEET TURNOVER OF AT LEAST 147 GPM. FLOW SHALL NOT EXCEED 200 GPM DUE TO DRAIN COVER FLOW RESTRICTION.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Chlorine observed at 0ppm. Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Records not available for review. Proper records must be available upon return visit. Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. End caps on far ladder missing. Replace.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter not operational, not bobbing, and stuck on 115gpm even when pump is turned off. Repair. Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Items stored within 3’ of pump - not 3’ of clear walking space available. Pool built 2003. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals in pump room. Pool built 2003.