| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) The pool operator must maintain records for at least six months. No records available for review. *permit item |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2537(7) Drain covers shall be in good condition and securely attached. Aquastar 6HP.. equalizer cover no longer in place. Open suction outlet present.
*immediate suspension item |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris. Debris in pool. *permit item
.2537 Multiple pool wall tiles at coping damaged/broken. Some tiles broken with sharp edges protruding into pool which could be a safety hazard for swimmer. Repair or replace damaged tiles. Plaster covering “NO STEP” tiles on in pool seating. Repair
*permit items |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Lid of skimmer on right side of pool far side has been sealed shut with concrete and cannot be opened. Repair. *permit item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Provide at least one handrail on steps. Hand rail on steps detached from pool decking. Repair. *permit item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Pool deck chairs within 6’ of edge of pool. This item is noted on multiple inspections. EHS recommends relocating to alternate area. *permit item |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Sign significantly faded and no longer in good repair. Repair or replace. *permit item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable. Kings III emergency phone system is not operable - appears to have no power. *immediate suspension item |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Automatic feeder system is not shutting down when circulation system is not in operation. Repair. *permit item |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(k) Provide shatterproof mirrors. Unable to determine if mirrors currently installed in restrooms are shatter proof. Ensure mirrors are shatter proof. |