Premises Information

Return to Inspections
NameCITRA LUX
Address1825 CARRINGTON OAKS DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/13/2023
Final Score @ Grade
40
General CommentsInspection conducted with operator Francisco Ventura. Immediate suspension of permit issued due to inoperable emergency phone and for missing suction outlet cover (equalizer cover). Once both items are corrected call Hope McIntosh at 980-229-7549. Pool closed with signs posted during inspection. Pool must remain closed with signs posted until suspension is lifted. At that time, all other permit items noted during the inspection today will be re-evaluated and if remain non-compliant, a 30-day intent to suspend the permit may be issued. Note: chlorine levels today greater than 10ppm. EHS recommends reducing levels.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) The pool operator must maintain records for at least six months. No records available for review. *permit item
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2537(7) Drain covers shall be in good condition and securely attached. Aquastar 6HP.. equalizer cover no longer in place. Open suction outlet present. *immediate suspension item
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Debris in pool. *permit item .2537 Multiple pool wall tiles at coping damaged/broken. Some tiles broken with sharp edges protruding into pool which could be a safety hazard for swimmer. Repair or replace damaged tiles. Plaster covering “NO STEP” tiles on in pool seating. Repair *permit items
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Surface skimmers shall be installed per manufacturer's instructions. Lid of skimmer on right side of pool far side has been sealed shut with concrete and cannot be opened. Repair. *permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Provide at least one handrail on steps. Hand rail on steps detached from pool decking. Repair. *permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Pool deck chairs within 6’ of edge of pool. This item is noted on multiple inspections. EHS recommends relocating to alternate area. *permit item
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Sign significantly faded and no longer in good repair. Repair or replace. *permit item
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Kings III emergency phone system is not operable - appears to have no power. *immediate suspension item
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Automatic feeder system is not shutting down when circulation system is not in operation. Repair. *permit item
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(k) Provide shatterproof mirrors. Unable to determine if mirrors currently installed in restrooms are shatter proof. Ensure mirrors are shatter proof.