Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCITRA LUX
Address1825 CARRINGTON OAKS DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/9/2021
Final Score @ Grade
16
General CommentsVisit to pool to lift suspension for water quality and conduct pre-permit inspection. At time of visit, suspension items have been corrected. Kings III has "Hideaway Lakes", advised manager to update establishment name. Lifted suspension. Changed to "A" Open for Business. Issued permit. No Night Swimming. Inspection with Franciso Ventura, Christopher Nunez, Miguel Espinal and Chris Cochran No signature due to COVID Pool not heated

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid recorded as 120 at time of inspection. Operator tested with test kit and verified correct reading was 100 ppm. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. Operator backwashed and is adding water to lower. Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets observed with debris and frogs. Two weirs stuck at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Ensure weirs are installed per manufacturer instruction and operable. Operator emptied baskets and adjusted weirs. Corrected.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Feeder not shutting off with pump at time of inspection. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Caribbean pool staff adjusted pressure valve and corrected to shut off with pump.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room, on floor and items within 3' of equipment. Pool built '03. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilet soiled in men's restroom at time of inspection. .2526(m) Keep restrooms and fixtures clean and in good repair.