3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 8.0 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8. Operator added acid and corrected to 7.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records being maintained for pool at time of inspection. Pool has been closed since suspension. No CPO on file.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Educated maintenance on testing pool water for records. Results recorded and will recheck at return visit. The pool owner shall maintain documentation that the person responsible for operating the pool has been trained on pool equipment operation, disease and injury prevention, pool water chemistry and regulatory requirements for public swimming
pools. A pool and spa operator certificate issued by the National Swimming Pool Foundation or other organization
that provides training on those subjects shall be accepted as meeting this requirement.
*ITS item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One handrail loose. One ladder loose at time of inspection. Keep tight and in good repair.
.2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy in disrepair at time of inspection.
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Operator replaced buoy with rope (50'). Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate not self-closing, self-latching at time of inspection. Fencing with gap greater than 4" on pool pump side of fence.
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".
*30 Day ITS item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room and on floor. Keep stored separately and off floor. Some items around piping and pump in equipment room within 3'. Pool built 2003.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
No labels on piping.
.2518(d) Piping and valves shall be labeled with color codes or labels. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Toilet paper missing in women's restroom. .2526(l) Provide toilet paper and dispensers in restrooms. |