| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records since May 10th. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers with organic debris stuck to the sides of the baskets. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
One skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket. - Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
One ladder > 6" from the pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
one ladder loose. .2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both gates propped open. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Polymetric sand is missing around one of the skimmers. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not functioning. .2518(g) Keep flow meter operational. - Intent to suspend item.
One of the filter pressure gauges not working. .2519(k) Provide operational pressure gauge on filter. - Intent to suspend item. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in women’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink. |
|