Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLUXE OF HUNTERSVILLE, THE
Address11504 ELMIRA AVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/22/2024
Final Score @ Grade
32
General CommentsInspection conducted with CPO Rudy Aguila. Immediate suspension issued 3) 15) 22) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH > 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook not attached to pole. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Immediate suspension item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Skimmer lid sunken roughly 1 inch below the pavers. Two other skimmer lids right at 1/2 inch. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Emergency phone not working. .2530(f) Emergency phone shall remain operable. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not functioning. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in the women’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.