Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLUXE OF HUNTERSVILLE, THE
Address11504 ELMIRA AVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/28/2023
Final Score @ Grade
14
General CommentsInspection conducted with CPO Roger Cooper. Outer rope on ring buoy heavily worn. Recommend replacing with new US Coast Guard approved ring buoy. Pool wall heavily damaged by ladder. Recommend repairing the pool wall. Intent to suspend issued 5) 17) 21)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Spotty record keeping for the last few months. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder missing endcaps. .2521 Install ladders per manufacturer instructions. One ladder > 6" from the pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Roughly 3/4 inch gap between pavers above one of the skimmers where polymetric sand is missing. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No One underwater light not fully installed, large gap between the bottom of the light and pool wall. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. - Intent to suspend item.