Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTRIVENI EXPRESS
Address9539 PINNACLE DR
SUITE 100
City/State/ZIP
CHARLOTTE NC 28262
Premise Type1 - Restaurant
CountyMecklenburg
Inspection Date 2/27/2026
Final Score @ Grade
96 A
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
37 1 Food properly labeled: original container No Yes No 3-302.12 Label all working containers of food (oils, spices, salts, flour, sugar) except food that is easy to identify such as dry pasta. Observed squeeze bottles of sauces and oils lacking labels. Improvement since last inspection. Label all working containers of food.
44 1 Utensils, equipment & linens: properly stored, dried & handled No Yes No 4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Observed several containers being stacked wet nested on clean storage shelf. CDI: PIC unstacked wet containers to allow for air drying. Repeat.
47 0.50 Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used No No No 4-501.12 Resurface or replace cutting surfaces that can no longer be effectively cleaned and sanitized. Deep scoring on cutting boards. Repair/replace as needed.
49 1 Non-food contact surfaces clean No Yes No 4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed build up on outside of stoves, prep counters and grill drawers. Clean as needed. Repeat.
55 0.50 Physical facilities installed, maintained & clean No No No 6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Clean floors under equipment. 6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture. Observed unsealed porous concrete blocks being used as footers under stove on left side of cook line. Seal or remove concrete blocks as they are not smooth and easily cleanable.