NameUPTOWN 550
Address558 E BROOKLYN VILLAGE AV
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/8/2025
Final Score @ Grade
24
General CommentsMAIN DRAIN COVERS EXPIRE 3/5/2029. DURING INSPECTION A RESIDENT WAS OBSERVED TO BRING A PET INTO THE POOL ENCLOSURE. DO NOT ALLOW PETS IN THE POOL ENCLOSURE. POOL IS APPROVED FOR NIGHT SWIMMING. THE OPERATION OF THE DECK LIGHTS AND POOL LIGHTS WAS OBSERVED DURING THE INSPECTION.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. Observed some gaps in the record logs. Ensure that all weekly and daily records are properly kept. No permit action taken.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed ladders to be loose and in need of securing.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy throw rope to be disconnected from the buoy. Rope was reconnected and made to the proper 50 foot length. -CDI
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed the mesh pattern of the fence and gate to be greater than .5 inches in length horizontally. These gaps must be corrected. I.T.S. Issued. Deadline is 11/7/2025
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed deck pavers and slabs to be damaged and in need of repair. Several were loose or damaged to the point of presenting a hazard. Observed 2 loose, unsecured depth marker tiles. Observed mortar to have fallen out of stone pavers at the pool edge. All of these must be corrected. Deadline is 11/7/2025.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Observed feeder system to not shut off when flow was stopped. This must be corrected. Deadline is 11/7/2025.