| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Daily records not maintained. Ensure daily record keeping for chlorine, pH and main drain checks. Weekly record keeping for total alkalinity and cyanuric acid. Intent to Suspend issued. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Main drains with some debris. Corrected during the inspection. Keep pool floor clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets full of debris. Keep clean to ensure system working properly. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder loose. Keep in good repair. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Inlet fitting missing off of one bubbler on sun shelf. Operator stated that fitting had been ordered. Replace fitting. Intent to Suspend issued. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope for ring buoy tangled. Keep accessible in case of emergency.
Rope for ring buoy starting to degrade. Replace with 50 ft. rope. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Audible alarm not audible on door from club area. Repair door to self-close, self-latch or self-close with audible alarm.
Meshing next to push bar gate exit. Meshing >1/2". Ensure openings no greater than 1/2" within 18" of push bar.
Intent to Suspends issued for above items. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pavers moved in some locations with openings >1/2" (near main drain section of pool and opposite side near sun shelf). Repair decking to ensure no openings/offsets greater than 1/2". Intent to Suspend issued.
Electrical box on deck where old light was in place. Provides trip hazard. Eliminate offset >1/2". Intent to Suspend issued.
Table located 4 1/2 ft. to pool. Maintain 6 ft. clearance around pool in all locations. Intent to Suspend issued.
Tumbled travertine coping. Areas on coping close to 1/2" offset. Monitor. May require repair in future.
Coping/deck corner at sun shelf with damage to edge of coping. Opening at 1/2". Repair to eliminate openings. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Liquid feeder not operable at time of inspection. Once repaired, ensure automated feeder detects flow of pump Stick feeder currently being utilized. |