11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder loose. Keep all handrails tightened and in good repair. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One fitting on bubbler damaged. Replace fitting to eliminate potential hazard to foot. Intent to Suspend issued. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Plexiglass loose on main gate. Repaired during the inspection. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool furniture <6 ft. to pool edge. Moved during the inspection.
Deck popping up >1/2" near gate entry area. Repair deck. Intent to Suspend issued. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automated chlorine and acid feeder. Not detecting flow when pump turns off. Automated systems shall detect flow and turn off system when no flow is detected. Intent to Suspend issued. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
Hose bib missing piece in pump room so hose is unable to be screwed on to end. Keep hose bib operational. Required in pump room. |