2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Pool chlorine at 0.3 ppm. Maintain at least 1.0 ppm. Per operator pool was closed due to high cyanuric acid but no pool closed signs were posted. Immediate Suspension issued.
.2535(4) Maintain chlorine at least 1.0 ppm. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 7.0. Maintain at least 7.2. Immediate Suspension issued.
.2535(1) Maintain pH at 7.2 to 7.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Alkalinity and acid not recorded weekly. Record weekly. ITS item.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some algea on pool floor due to lack of chlorine.
.2537(14) Keep pool surface and pool floor free of debris. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back gate not self-closing and not self-latching. ITS item.
.2537(b) All gates and doors shall be self-closing, self-latching.
Window limiters removed from windows in one unit located to right of main entry off leasing office. ITS item.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet due to leak at filter. Keep dry.
.2533(d) Pump room floor shall be kept dry and free of standing water. |