Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHAVEN AT RIVERGATE, THE
Address14710 KILKENNY HILL LANE
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/10/2019
Final Score @ Grade
16
General Comments25 - No fresh air intake in chemical storage room or pump room. Required per mechanical inspector. Verify with engineer on sizing. 30 days given for repair. Battery back-up verified at time of inspection. PDSC form verified at time of inspection. Intent to suspend issued for log book, weir, autofill cover, and gates/fencing.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed pool pH at 8.0 for 6/10. Operator indicated chemistry was adjusted by chemical addition. Provide section in log book for notes and comments. Intent to Suspend issued.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer missing weir. Replace weir. Intent to Suspend issued.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Autofill missing fitting. Provide fitting to eliminate 2" opening in side wall to prevent entrapment hazard. Intent to Suspend issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No All gates with 1" between post and gate at hinge location. Maintain no openings >1/2" within 18" of latch mechanism. Gate (left side) with >2" under gate from ground to bottom horizontal. Maintain 2" or less under gates. Observed fencing with >2" under fence from ground to bottom horizontal on right side fence and gate. Maintain 2" or less. Intent to suspend issued.