5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
pH, chlorine, and main drains must be checked once a day and recorded every day the pool is open. Total Alkalinity and Cyanuric Acid (if Cyanuric Acid is in use) must be checked once a week, 100ppm maximum for Cyanuric Acid. Observed gaps in the log book record. Keep proper records for all daily and weekly requirements. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed 1 weir missing out of 6 total. No Permit Action. More than 50% of weirs in place. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy throw rope to be 60 feet long. 50 foot length is required for this pool. Rope was corrected to the proper 50 foot length. |