Premises Information

Return to Inspections
NameASCENT PINEVILLE
Address8401 HABERSHAM POINTE CIR
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/12/2022
Final Score @ Grade
26
General CommentsCPO Tyrone was present during the pre permit pool inspection. EHS has noted some damage to occur to pools edge near 4 foot side near grill, ensure damage does not exceed .5in in offset and there shall be no loose coping. Night Swimming is NOT permitted.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. - Observed floating debris throughout the pool surface and some leaf debris on bottom of pool floor. EHS able to verify main drains. CDI- CPO started cleaning debris during the inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in pool skimmers. CDI- CPO cleaned floating debris in skimmers.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed ring buoy throw rope to be 40ft. Per field book manual pool is required to have 50ft throw rope. CDI- CPO provided a new 50 ft throw rope for the ring buoy.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Observed single door to leasing office restroom open directly to pool deck without an alarm and to be self latching. CDI- CPO provided an audible alarm to the door.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Observed two large pants within 5Ft of pools edge. CDI- CPO moved plants to at least 6 ft away from pools edge.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(k) Provide shatterproof mirrors. - EHS unable to verify rest room mirrors are shatterproof. CPO unable to provided documentation of mirrors to be shatterproof.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. - Observe hose near chemical/pump room without a proper back flow device attached.