Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePROXIMITY NORTHLAKE
Address4212 NAPA OAK DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/20/2025
Final Score @ Grade
14
General CommentsInspection conducted with CPO Marcos Rada. Heater off at time of inspection. Did not check water temperature. Filtration and feature pump labels missing. Verified pump horsepower matched. Lintel above the skimmers heavily rusted. Recommend replacing with PVC, or other, inert material. If it continues deteriorating, the pool may be closed by Public Health until the steel plate has been replaced to protect the health and safety of bathers. Intent to suspend issued 12)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 1 of 6 weirs missing. .2518(k) Provide functional weirs. Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. .2521 Install ladders per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing for autofill. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak at salt generator. Standing water on pump room floor. .2533(d) Pump room floor shall be kept dry and free of standing water.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One soap dispenser broken in men’s restroom. One soap dispenser missing in women’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.