Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePROXIMITY NORTHLAKE
Address4212 NAPA OAK DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/28/2025
Final Score @ Grade
32
General CommentsInspection conducted with Miquel Espinal and CPO Marcos Rada. Heater off at time of inspection. Did not check water temperature. Filtration and feature pump labels missing. Verified pump horsepower matched. Lintel above the skimmers heavily rusted. Recommend replacing with PVC, or other, inert material. If it continues deteriorating, the pool may be closed by Public Health until the steel plate has been replaced to protect the health and safety of bathers. Items marked as Intent to Suspend must be corrected before permit expires on 5/31/2025 in order for 2026 pool permit to be issued. Immediate suspension issued 6) 15) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No One of the WAV12WR main drain covers damaged. .2537(7) Drain covers shall be in good condition and securely attached. - Immediate suspension item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 1 of 6 weirs missing. .2518(k) Provide functional weirs.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Top of bubbler missing on sunshelf. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Outer rope on ring buoy and throw rope heavily frayed. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4 inch in diameter. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Spare pump basket for filtration pump not observed. .2518(e) Provide a spare basket for pump. - Intent to suspend item. Flow meter not working. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some of the labeling on pool equipment piping worn off. .2518(d) Piping and valves shall be labeled with color codes or labels.