Premises Information

Return to Inspections
NamePROXIMITY NORTHLAKE
Address4212 NAPA OAK DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/1/2024
Final Score @ Grade
16
General CommentsInspection conducted with Miquel Espinal. Filtration pump missing label. Observed Hayward pump with 5 HP motor. Feature pump missing label. Observed Hayward pump with 3/4 HP motor. Outdoor pool with a heater. Heater off at time of inspection. Lintel above the skimmers heavily rusted. Recommend replacing with PVC, or other, inert material. If it continues deteriorating, the pool may be closed by Public Health until the steel plate has been replaced to protect the health and safety of bathers. Intent to suspend issued 5) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Chlorine, pH, Total Alkalinity, and Cyanuric Acid the same every day for the past few months. No Main drain checks. Ensure chemicals are tested with a test kit and recorded daily. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing. .2518(k) Provide functional weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both ladders loose. Some ladder steps loose. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Post-May 2010 fence with some gaps > 2” under the fence. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Standing water on pump room floor. .2533(d) Pump room floor shall be kept dry and free of standing water. Both lights burned out in pump room. .2533(b) Provide sufficient lighting in pump room.