Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePROXIMITY NORTHLAKE
Address4212 NAPA OAK DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/3/2021
Final Score @ Grade
20
General CommentsInspection conducted with inspector Naly Lor and maintenance staff. Due to COVID-19 precautions, inspection was not signed by maintenance. No label on pool feature pump. Verified that it is a Hayward pump with 3/4 HP motor. Appears to be the originally installed pump. Lintel above the skimmers heavily rusted. Recommend replacing with PVC, or other, inert material. If it continues deteriorating, the pool may be closed by Public Health until the steel plate has been replaced to protect the health and safety of bathers. Immediate suspension issued 15) 22) Contact Will Harrison (704-507-6824) to schedule re-inspection when issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Two weirs missing. .2518(k) Replace missing weirs. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders loose. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope snapped off. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4 inch in diameter. - Immediate suspension item.
22 6 Premises: emergency telephone provided No No No Emergency phone call back number went to office voicemail. .2530(f) Emergency phone shall remain operable and be able to accept incoming calls. Update emergency phone signage with phone number for emergency phone. Number must match what 911 has. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemical storage room fan not functioning. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Leak at pool filter. .2533(d) Pump room floor shall be kept dry and free of standing water.