Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMILL, THE
Address11015 EDUCATION WAY
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/22/2021
Final Score @ Grade
36
General CommentsInspection conducted with Daniel May. Due to COVID-19 precautions, inspection was not signed by the operator. Note: Rainy day, main drains were very difficult to see when it wasn't raining. Ensure that pool is closed any time main drains are not clearly visible from the pool deck. Facility in the process of installing liquid chlorination system, control board installed. Ensure chemicals are stored in an approved chemical storage room meeting rule .2434. Current pool chemical storage room is located on the pool deck, away from pump room. Observed missing lug screw from last inspection replaced with steel screw attaching boning wire to pump motor. Plastic wire nut connecting bonding wire sections. Electrical permit and inspection from Code Enforcement not obtained. G.S. 130A-2(3) Ensure boding wire is properly attached by a licensed electrician and electrical permit and passing inspection are obtained from Code Enforcement. Broken glass on the pool deck by the emergency phone. G.S. 130A-2(3) Maintain pool deck free of broken glass. - Corrected. Inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling a follow up inspection. This can be done by calling our main office (980) 314-1620 and paying with a credit card. Permit Denied G.S. 130A-2(3) - Bonding wire 3) 7) 16) 22)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent total alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Corrected. Operator tested at 120ppm.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor and walls with black algae growing. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer not functioning, turned off in the pump room. .2518(k) The flow through rate for each skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Post-2010 fencing with gaps as much as 5" under the fence. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Pre-permit item. Post-2010 fencing < 48" in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Unable to call emergency phone, goes to voicemail. Does not immediately hang up after calling Kings III. .2530(f) Emergency phone shall remain operable and be able to accept incoming calls. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in the pump room instead of chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. - Corrected.