| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records being kept. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Leaves and debris floating on the surface, largely due to water level above the skimmers. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
Pool floor and walls with debris and black algae growing. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Water above the skimmers, floating debris not going into the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Pre-permit item.
One skimmer not functioning, turned off in the pump room. .2518(k) The flow through rate for each skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50. - Pre-permit item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy heavily worn, outer rope deteriorated. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope at least 1/4" in diameter. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Post-2010 fencing with gaps as much as 5" under the fence. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Pre-permit item.
Post-2010 fencing < 48" in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier - Pre-permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some tiles offset by ladder creating a trip hazard. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone is busy when trying to call. Does not immediately hang up after calling Kings III. .2530(f) Emergency phone shall remain operable and be able to accept incoming calls. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pool built without a vacuum line. Vacuuming through one of the skimmers. .2518(f) Skimmer vacuums may only be used for pools with two or fewer skimmers. Pool permit restriction to provide a portable vacuum to clean the pool. - Pre-permit item.
Flow meter stuck. .2518(g) Keep flow meter operational. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Most chemicals stored in pump room or general storage area instead of chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Fan not functioning in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Corrected, breaker turned back on. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower sign not posted. .2526(a) Post a shower sign visible upon entrance to the pool. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in men's restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.
Urinal not working in men's restroom. .2526(m) Keep restrooms and fixtures clean and in good repair. |