Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePROVIDENCE ROW
Address5350 PINEHURST PARK DR
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/8/2026
Final Score @ Grade
24
General CommentsIssued 30 day Intent to Suspend (ITS) for gate, replace flitting on sunshelf, provide spare pump baskets, keep flow meter operational. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Night Swimming needs verification sent before dawn, after dusk or onsite visit for re-certification. Expired 5/9/2026. Must verify lighting is sufficient to see bather entrances, pool water, floor, main drains, emergency equipment and deck clearance. Pool not heated. Work has been done in pump room. Electrical permits have not been passed/been approved. Ensure electrical permits are passed and any required paperwork is submitted for approval. Permit will not be issued 2027 permitting season without approved permits. Advised keeping pool voluntarily closed until all issues addressed. “W” ITS status *Note: Unable to accurately identify PDSC information due to lack of correct labeling/unapproved electrical changes in pump room and operators unaware of changes. Note in file indicated in field plan review was needed for changes and one staff member indicated a motor change recently. Possible pump changes. Took photos and will follow up with pool seniors, supervisors and property management. There does not appear to be imminent hazard or suction issue. Appears to be written documentation missing/incorrect and changes made without approval on electrical and labeling side.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder with missing step. Replace. .2521 Install per manufacturers instruction
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One bubbler fitting missing on sunshelf. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *permit item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Front gate not latching and stuck on concrete when opened fully. .2537(b) All gates and doors shall be self-closing, self-latching. *permit item
22 6 Premises: emergency telephone provided No No No Phone number missing on pool phone information. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator added number and corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational. No spare pump basket. .2518(g) A flow meter, reading in gallons per minute shall be installed per manufacturer instructions. .2518(e) Provide a spare basket for pump. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items within 3 foot of equipment. Dry bag of chemicals on floor in chemical storage. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Pipes not clearly labeled. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels.