3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8.
PH observed above 8.0 |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs.
One out of three weirs missing. Weir replaced. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Face plate missing between 3 1/2ft and 4ft markers. Operator replaced face plate. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching.
Gate near stairs getting stuck on concrete and not self closing.
Gate by clubhouse doors not self latching. Clubhouse doors and other gate could act as barrier but doors are not self closing self latching and are not equipped with alarms.
Operator repaired inner fence gate.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 1, 2010).
Openings greater than 4” under certain parts of the fence due to eroded landscaping.
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
Windows off gym open and have no limiters. Install limiters.
.2528(b) Gates may only swing toward pool if built prior to May 1, 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool.
Gate near stairs swings towards pool due to topography. Built in 1988. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2".
3/4in cap sticking out of deck profile near ladder |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep the flow meter operational.
One flow meter not operational. Operator repaired. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. |