5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Missing drain cover check on record sheet. Added it as a column to check daily. Emailed a copy of Mecklenburg County’s pool record sheet if they wish to use that in the future. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. One ladder was loose on one side. Operator advised he would tighten the bolt. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pool fence is 45-46” depending on ground level.
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed gap in fencing between the posts and the first vertical where it measured 4.5”-5”
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. The access gate at the steps swings toward the pool due to the steep steps leading up to the gate and pool.
Pool built pre-2010. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(b) Provide sufficient lighting in pump room. Light in pump room is not functional.
.2533 Provide continuous forced ventilation or cross ventilation in pump room and chemical room. Neither area had forced/cross ventilation. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. No air gap observed. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
There was no backflow preventer on one faucet near the front gate. |