11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Observed rubber bumpers missing from ladder. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
.2521(b) Contrasting color band shall be clearly visible. Contrasting color band starting to fade. Correct as may prevent permit in 2027 |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed a brand new ring buoy rope. Rope measured above 38 feet in length. CDI- Rope was cut down to 38 feet in length. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed side gate latch not self-closing and self-latching. CDI, gate latch corrected and now self-closing self latching.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
Observed opening between 6” and 8” between grade and bottom horizontal. Pre-2010 construction |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(b) Provide sufficient lighting in pump room. Observed light not working in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |