NameCANOPY AT BAYBROOK I
Address6609 REAFIELD DR
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/4/2023
Final Score @ Grade
32
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool showed an original reading of 7.0. Rechecked at the end of the inspection. Pool measured at 7.2 on the recheck.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool’s surface.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed surface skimmers with debris inside.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Observed pool depth marker not fully attached inside of the pool.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed missing endcaps on ladders .2521 Install ladders per manufacturer instructions. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Observed one ladder greater than 6 inches away front the pool wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed a brand new ring buoy rope. Rope measured above 38 feet in length. CDI- Rope was cut down to 38 feet in length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed foot holds around building with bricks making steps. Pre-2010 .2528(b) Horizontals shall not be located less than 30" in height. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed one gate no self latching.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed floor inside of the pump room with wet.