Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFOUR POINTS CHARLOTTE - LAKE NORMAN
Address16508 NORTHCROSS DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/30/2024
Final Score @ Grade
24
General CommentsInspection conducted with inspector Jordan McClenic. Poor indoor air quality. Nose and eyes burned during inspection. Maintain proper water chemistry and ensure proper air circulation in pool area. Chlorine consistently 1ppm and was regularly shocked the month of January. Chlorinator turned all the way up. Recommend taking samples to a pool water testing location for additional troubleshooting assistance if there are issues maintaining proper water balance. Immediate suspension issued 2) 3) 22) Contact Will Harrison (704-507-6824) to schedule re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level. - Immediate suspension item.
3 6 Water quality: pool water pH No No No PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Total Alkalinity and Cyanuric Acid checks spotty. No readings in the last 3 weeks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Emergency phone not able to dial out to 911. .2530(f) Emergency phone shall remain operable. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan turned off in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Corrected.