5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Total Alkalinity and Cyanuric Acid checks spotty. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
Cyanuric acid at 0ppm for the last month. Tested today at 100ppm. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Immediate suspension item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan turned off in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Corrected.
Leak at flow meter for the chlorinator. .2533(d) Pump room floor shall be kept dry and free of standing water. |