Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePACES POINTE - WADING
Address10516 PACES AVE
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type54 - Year-Round Wading Pool
CountyMecklenburg
Inspection Date 9/21/2022
Final Score @ Grade
26
General CommentsPOOL IS CLOSED TO SWIMMING BY ORDER OF THE HEALTH DEPARTMENT. CONTACT C. ELMORE WHEN THE CORRECTIONS ARE MADE. 704-507-6814

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH. to be 6.8. Correct pH.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed records not being properly kept. Keep the records as required. Observed cyanuric acid and total alkalinity not being properly kept.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed fence not built to current specifications. Fence built prior to 2010. No permit action taken.
22 6 Premises: emergency telephone provided No No No Observed 911 to give address of 10501 Paces Ave. rather than 10516 Paces ave. 10501 is the address for the other pool on the property. Pool is closed to swimming. I.S. Issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(e) Provide a spare basket for pump. .2518(g) Keep flow meter operational. Observed flow meter stuck. Correct flow meter. Observed pump running without basket installed. Install basket and also provide spare of the same.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at the backwash line.