Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePACES POINTE - WADING
Address10516 PACES AVE
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type54 - Year-Round Wading Pool
CountyMecklenburg
Inspection Date 9/15/2021
Final Score @ Grade
22
General CommentsCPO AGREED TO EMAIL COPY OF REPORT NO SIGNATURE DUE TO COVID-19 PRECAUTIONS. CONTINUE TO FOLLOW ALL RELEVANT COVID RULES

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH at 6.8 or less. 7.2-7.8 is safe range. IS issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No pH, chlorine, and main drains must be checked once a day and recorded every day the pool is open. Total Alkalinity and Cyanuric Acid (if Cyanuric Acid is in use) must be checked once a week, 100ppm maximum for Cyanuric Acid. Observed gaps in the log book record. Keep proper records for all daily and weekly requirements.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence not up to current specifications. Fence built prior to 2010. No Permit Action taken.
22 6 Premises: emergency telephone provided No No No Observed kings III box non-functional. Box speaker appears not to function. Box must function and have a working call-back number that is posted with local 911 service along with the proper address. Proper address and call-back number must be correct and on file with local 911. PERMIT SUSPENDED POOL CLOSED TO SWIMMING. Contact C. Elmore when correction is made. Box must function. Pool cannot open back up until after the Health Department verifies corrections.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line has no air gap.