Inspection Date 9/3/2025
Final Score @ Grade
18
General CommentsInspection conducted with CPO Randy Frack. Outer rope on ring buoy and throw rope fraying. Recommend replacing with new US Coast Guard approved ring buoy with attached 30 foot throw rope at least 1/4 inches in diameter. Decking around ladder chipped, some caulking missing from expansion gaps and some gaps between deck drains. Maintain deck with no gaps or offsets > 1/2 inches. Static on emergency phone line. Recommend having phone company/Kings III check emergency phone. Permit condition that flow meter read between 59 and 63 GPM. Verified at 63 GPM.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. Hole in the deck where one of the volleyball net poles go. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One faucet in men’s and one faucet in women’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair.