NameBRIDGES AT MALLARD CREEK
Address7916 HARRIS HILL LN
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/15/2025
Final Score @ Grade
32
General CommentsInspection conducted with CPO Randy Frack. Pool re-plastered. Equalizer lines planted over on pool walls. Now have tiled contrasting color bands. Verified PDSC information for new drain covers. Outer rope on ring buoy fraying. Recommend replacing with new US Coast Guard approved ring buoy. Decking around ladder chipped, some caulking missing from expansion gaps and some gaps between deck drains. Maintain deck with no gaps or offsets > 1/2”. Mirrors were changed last year, do not have documentation that mirrors are shatterproof or have safety backing. Will need to provide documentation before 2026 pool permit will be issued. Intent to suspend issued 8) 17) 24) Have until 5/31/2025 to make corrections before current permit expires. Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir not fully installed. .2518(k) Provide functional weirs. - Corrected. Observed skimmer equalizer valves installed. Will need to remove and abandon equalizer lines per state guidelines. .2518(l) Skimmer equalizer lines shall be in compliance with ANSI/PHTA/ICC-7 or disabled by plugging the line under the skimmer basket and on the pool wall. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate to patio not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected. Pre-2010 fencing with gap > 4” through fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4".
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and umbrella too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No I corrected phone number posted for emergency phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pool recently replastered. Vacuum cap not installed. Vacuum off in the pump room. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Bag of dry chemicals stored on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One faucet in men’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair. New mirrors. Not able to determine if shatterproof or have safety backing. .2526(k) Provide shatterproof mirrors.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Fill spout directly on pool deck and extends > 2 inches into the pool. .2512(c) Over the rim fill spouts shall not protrude greater than two inches beyond the edge of the pool and shall be at least two pipe diameters above the pool.