General CommentsInspection conducted with CPO Randy Frack. Contrasting color bands fading. Prior to 2025 permit being issued. Will need to repaint at least 2” wide contrasting color band at leading edge of pool steps. Takes a while for Kings III to connect when calling back to the box. Recommend to have Kings III adjust to connect in 3 rings or less. Intent to suspend issued 5)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No place on log sheet for main drain checks. No records for the weekends. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladder missing endcaps. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope not attached to ring buoy. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Hole in the deck where one of the volleyball net poles go. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Bag of dry chemicals stored on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One faucet in men’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair. New mirrors. Not able to determine if shatterproof or have safety backing. .2526(k) Provide shatterproof mirrors.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Hose Bibb for restrooms not observed. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.