5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No place on pool log sheet for main drain checks or pool maintenance activities. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections,and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. Operator will use state log sheet. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Safety signage in less than 1 inch lettering. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected. New temporary signage in place. Permanent sign ordered.
Safety signage in less than 1 inch lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Corrected. New temporary signage in place. Permanent sign ordered. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
One faucet in men’s restroom not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair. |