Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBRIDGES AT MALLARD CREEK
Address7916 HARRIS HILL LN
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/1/2020
Final Score @ Grade
16
General CommentsInspection conducted with Lamar Richardson. Due to COVID-19 precautions, inspection was not signed by the operator. Issues from previous inspection corrected, including contrasting colorband repainted. Out of paper towels in women's restroom. Recommend restocking. Permit issued. No Night Swimming “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders extend > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
22 6 Premises: emergency telephone provided No No No Part of address faded on emergency phone sign. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light not working in the pump room. .2533(b) Provide sufficient lighting in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Vacuum line not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One of the faucets in the men's restroom not working. .2526(m) Keep restrooms and fixtures clean and in good repair.