Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMADDOX SOUTH END
Address2630 SOUTH BLVD
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/31/2023
Final Score @ Grade
10
General CommentsInspection conducted with operator, Wesley Norris. 30 day Intent to suspend the permit issued due to inaccurate/incomplete record keeping, missing limiters on windows and furnishings adjacent to fencing on resident patios leading directly onto pool deck. EHS will return at 30 days to verify records are completed daily and are accurate, window limiters are in place, and furnishings which could be foot holds is relocated away from fencing. Note: Aquastar drain covers for feature pump expire 3/1/2024. Replace covers and submit pdsc for approval prior to cover expiration in order to avoid permit action. Pool is not permitted for night swimming. Ensure posted hours indicated pool open for swimming only until dusk.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Records not complete and not accurate. Pool water chlorine documented as range of 5-10 which dose not accurately reflect the 1.0ppm cl in the pool. Pool water pH recorded daily at 7.2 which also does not accurately reflect 7.6 found during inspection. Chlorine and pH readings documented never change which is not representative of actual pool chemistry. No main drain checks documented during July. No TA or CYA readings documented. Chlorine and pH readings not listed in proper column. *permit item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed windows leading directly onto pool deck missing limiters. All windows that open directly to the pool deck must be limited to no more than 4” opening or have audible alarm. *permit item .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Pool constructed 2019. Resident furnishings pushed adjacent to fencing on patios leading directly onto pool deck which is resulting in foot holds. Move furnishings that could be used as foot holds away from fencing on resident patios. *permit item
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(h) Shower(s) shall be provided. Shower present but not operational.