15
|
0
|
Food separated & protected |
Yes |
No
|
No |
3-302.11(A)(8) Separate unwashed produce from ready-to-eat foods. For more information on food storage order please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation Observed several unwashed produce items being stored on top shelf of reach in cooler above ready to eat foods. CDI: PIC re-arranged items to proper storage order. |
|
23
|
3
|
Proper date marking & disposition |
Yes |
Yes
|
No |
3-501.18 Discard the food requiring date labels once time/temperature window has expired, if it has not been labeled, or if the label is incorrect. -P The PIC should train and assign staff to monitor date marking to prevent the use of food products that are no longer in compliance with 3-501.17 (A), (B), or (C) For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Date Marking Food Safely https://youtu.be/BOPsSNUajYs . Observed a container of rice and two containers of salsa being stored in reach in cooler and a container of beans in prep flip top cooler all missing date marks. CDI: PIC date marked all items. REPEAT. |
|
44
|
0
|
Utensils, equipment & linens: properly stored, dried & handled |
Yes |
No
|
No |
4-903.11 (B) After cleaning and sanitizing, clean equipment and utensils shall be stored in a self-draining position that allows air drying and covered or inverted. Observed a stack of metal containers being stored wet nested on clean storage shelf. CDI: Containers were unstacked to allow for air drying. |
|
47
|
1
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-501.11 Maintain equipment in good repair. Observed torn gasket on reach in cooler and low boy cooler and missing handle for lid of flip top cooler. Replace torn gaskets and missing handle. REPEAT. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed large tear in metal flooring of MFU being covered with a piece of cardboard. Replace torn flooring and remove cardboard from floor. REPEAT. |