11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One handrail loose. .2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
One buoy rope long at time of inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator corrected (37') |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gates had closer installed with reinforcement bar, creating horizontal less than 45" in height, at time of inspection. .2528(b) Horizontals shall not be located less than 45" in height. Operator removed horizontal (whole piece) and corrected, but would like further guidance for permanent solution to gate issue/compliance. Spoke with T. Dutcher and confirmed this temporary solution was permitted and will work with department to ensure changes to gate are in compliance. **Note: Hinge may not meet compliance if installed less than 45". |