5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed new log books from previous inspection. Log book without main drain/VGB section. Some daily record keeping missing from temperature logs in January. Provide log book with section for drain checks and ensure daily record keeping. Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some build-up/mildew around skimmer casings inside skimmers. Keep clean. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy provided but not USCG approved. Spa is not required to have ring buoys. Removed from deck during inspection. If provided, must be USCG approved and meet ring buoy rope length requirements. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Small leak at flow meter for chlorinator. Repair leak to ensure meeting NSF approval. Leak not enough to drip on floor. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Bicarb stored in pump room. Chemical storage room is located in separate building. Maintain chemical storage up off floor and in approved chemical storage room. |