General CommentsInspection completed with Andrew Nosal present. Intent to suspend permit issued for items listed below. Correct these items by May 31, 2026 or the local county permit will not be issued. 1. 5 % accurate flow meter installed per manufacturers instructions on piping. 2. ‘Adults should not swim alone’ sign posted in minimum 1 inch lettering with exact wording. 3. Missing depth tile on interior pool wall near ladder. 4. Loose depth tile and no dive tile near pool ladder. Requires 5% flow meter for 2026. Permit Restriction: Flow meter must remain operable with flow at 124 gpm to 150 gpm to meet turnover and flow restriction main drains. Suction Hazard.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.6ppm. CDI- adjusted to 1.0ppm.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Observed one loose depth marker and ‘no dive’ marker on pool deck near ladder. Observed one depth marker on interior pool wall missing. Provide depth markers spaced no greater than 25 feet apart. Intent to suspend permit issued. Correct within 30 days or permit may be suspended.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladders with missing rubber end caps. Replace.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed water overflow grate damaged and in poor repair. Replace.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed some areas of fencing near back gate with greater than 4 inches of clearance. No permit action taken due to construction date of pool.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed this sign not posted on pool deck. Provide. Intent to suspend permit issued.