Premises Information

Return to Inspections
NameAVANA RESERVE
Address1315 CAMERON MATTHEWS DRIVE
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/8/2020
Final Score @ Grade
14
General CommentsC. Elmore evaluated the gauges set up for demonstrating TDH on the system. The systems was backwashed with C. Elmore present and then put into service. The PSI gauge read 20PSI for the discharge pressure, the vacuum gauge read 15.5 In. Hg. Using the formula (discharge pressure reading x2.31)+(Suction pressure reading x1.13)=TDH, C. Elmore got a TDH of 63.72 for this system. As this is greater than the reported TDH 56.37 the system does not currently present a suction hazard with the drain covers installed. PAPER PERMIT WILL BE AVAILABLE ON-LINE SO THAT IT CAN BE PRINTED OUT BY THE FACILITY MANAGEMENT. IT MUST BE PRINTED OUT AND POSTED WHERE IT IS VISIBLE FROM THE POOL DECK AREA. STICKER ISSUED. POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed no section for checking main drains on a daily basis on the log sheet. Main drains as a daily check was added as a section to the log sheet. -CDI.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladders to be missing their rubber bumper feet. Provide them.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed vacuum line missing a cover. Cover was provided. -CDI
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gaps under and through the fence greater than 4 inches. Fence was built prior to 2010. No permit action taken.