Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePRESERVE AT STEELE CREEK
Address10836 MORGAN CREEK DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/2/2019
Final Score @ Grade
16
General CommentsNo local permit stickers (pool now seasonal) available at time of pre-permit inspection. Allowed operator to open pool and will issue local 2019 permit sticker as soon as possible. No Night Swimming allowed. CPO Carlos Caldas (Exp 2023). *Note: RIng buoy currently in good repair with becketts attached, but may need replacement soon.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No At time of visit, one ladder step slightly crooked, but secure. Ladder loose at deeper end of pool. Keep tight and in good repair. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One gate not latching at time of visit. .2537(b) All gates and doors shall be self-closing, self-latching. Operator corrected to self-latch. Some horizontals on fence3s less than 45" (but above 30") .2528(b) Horizontals shall not be located less than 45" in height. Pool built prior to 2010.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No At time of visit, automatic feeder not turning off when circulation pump turned off. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Operator corrected so feeder turned off with pump. Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational at time of inspection. .2518(g) Keep flow meter operational. Operator corrected.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Piping labels starting to fade. .2518(d) Piping and valves shall be labeled with color codes or labels.