Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHAWTHORNE AT THE GREEN
Address13625 HAVEN RIDGE LN
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/20/2019
Final Score @ Grade
28
General CommentsDecks chipping in places. Maintain deck with no gaps or offsets > 1/2 inch. Prior to making any equipment changes, you will need to fill out an In-Field Plan Review application. This can be found at our website, Meckpools.Charmeck.org. Submit this to our office with the newly installed pump information to ensure it works with existing equipment. Any time electrical work is done a permit is required from Code Enforcement. Ensure that proper permits are obtained from Code Enforcement for the pump replacement. Immediate suspension issued 6) In field plan review and updated PDSC form will need to be approved by our office prior to lifting the suspension.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No New Pentair WhisperfloXF pump installed in July 2019. Pump, model XFE-20 has a max flow of 290 gpm. Main drains only capable of 224 gpm. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder missing endcaps. Corrected by operator. Same ladder extends > 6 inches from the pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing cover for one of the floor returns. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates with diagonal support wire. .2528(a) Diagonal members on fence and/or gate shall not exceed 1.75 inches. - Intent to suspend item. Fence < 48" in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Both underwater lights not tightly installed. Corrected by operator.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(e) Provide a spare basket for pump. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Light not functioning in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Pump room used for general storage. Items stored beside the equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms 141.8F. Maintain at 110F or less.