6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2537(7) Drain covers shall be in good condition and securely attached.
Observed equalizer cover missing from wall.
CDI CPO replaced equalizer cover during inspection. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs.
Observed one of the two weirs missing.
Replace.
INTENT TO SUSPEND ITEM. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background.
Observed NO DIVING stencils rubbed off and barely legible.
Re-stencil NO DIVING markers on pool deck.
INTENT TO SUSPEND ITEM. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed ring buoy rope measuring greater than 30ft.
CDI CPO corrected during inspection to measure approximately 30 ft. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Observed a few cracks on pool deck measuring greater than 1/2 inch.
Repair cracks to prevent hazards.
INTENT TO SUSPEND ITEM.
.2537(3) There shall be no loose coping.
Observed damaged/loose coping near ladder.
Repair coping to prevent hazards.
INTENT TO SUSPEND ITEM. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational.
Observed non-operational flow meter.
CDI CPO was able to correct during inspection and flow meter was operational. However, flow not within range of permit restriction.
IMMEDIATE SUSPENSION ITEM.
.2518(i) Return inlets shall be replaced when damaged or missing.
Observed damaged return inlet on pool wall.
Repair.
INTENT TO SUSPEND ITEM.
.2518(e) Provide a spare basket for pump.
Observed no spare pump basket.
Obtain spare pump basket.
INTENT TO SUSPEND ITEM. |