Premises Information

Return to Inspections
NameSHARON CROSSING
Address2123 EL VERANO CIRCLE
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/8/2024
Final Score @ Grade
20
General CommentsMet with operator Jonathan Montalvo. Inspection conducted by Anglecia Askew under supervision of Devon Moeller. IMS issued for new drains. Submit updated PDSE to health department for drain approval. Bathroom flooring scheduled to be replaced by the end of February. 2024 permit shall not be issued until flooring is replaced and approved. Submit slip resistant flooring documentation to the health department for approval prior to the installation. Call EHS Devon Moeller when items have been complete and ready for reinspection. 704998112.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Some test reagents expired. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Cyanuric acid reading missing from several weeks. Maintain weekly cyanuric acid reading records.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Main drain covers replaced without health department approval or receipt of updated PDSE. Submit new PDSE for approval. Immediate suspension item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope measured at 28’. Operator corrected to 30’ and replaced rope.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap in both restrooms.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. Flooring in both restrooms in poor repair - peeling at seams no longer smooth/cleanable and possibly present trip hazard.