Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHARON CROSSING
Address2123 EL VERANO CIRCLE
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/3/2019
Final Score @ Grade
34
General CommentsObserved chlorine pucks on the pool bottom. Pucks cannot be in the pool when it is open. Observed pool pump switched out. Mecklenburg County Health Department has no record of this change. This must be resolved with the Health Department. The pool cannot reopen for swimming without Health Department follow-up inspection and approval. Permit Suspended. Electrical inspection may also be required.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Observed Intelliflo VSF pump with 3HP motor installed. Mecklenburg County Health Department does not have record of this pump being installed on this system. Permit is suspended. Pool must remain closed to swimming until Health Department approved reopening.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed skimmer basket damaged to the point that debris is passing into the pump. Replace the skimmer basket.
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No Observed breakpoint rope not in place.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed 1 missing eyeball fitting from the returns. Observed vacuum port to be open and not have the cap on. Provide vacuum port cover.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ring buoy throw rope to be 33ft. long. Corrected to 30ft. as required. -CDI
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed furniture to be too close to the water edge. Items must be back at least 6 feet. -CDI Items were moved.
18 4 Premises: lifeguards present or warning signs posted No No No Observed warning signs not properly posted. Proper warning signs with correct language and letter heights must be posted.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at the backwash line.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Observed no shower sign posted.